Table 3-6. Call Setup Result Codes

Code

Definition

0

No previous call (modem log has been cleared since any previous calls)

1

No dial tone detected

2

Reorder signal detected, network busy

3

Busy signal detected

4

No recognized signal detected (e.g., no signal, or nothing recognizable)

5

Voice detected * if this is a voice modem (e.g., V.253) operating in voice mode (e.g.,
+FCLASS=8.0)

7

Data Answering signal detected (e.g., V.25 ANS, V.8 ANSam)

8

Data Calling signal detected (e.g., V.25 CT, V.8 CI)

9

Fax Answering signal detected (e.g., T.30 CED, DIS)

A

Fax Calling signal detected (e.g., T.30 CNG)

B

V.8bis signal detected

Table 3-7. Multimedia Modes

Code

Definition

0 Data

Only

1 Fax

Only

2 Voice

9 Video-telephony,

H.324

A

Other V.80 call

Table 3-8. DTE-DCE modes

Code

Definition

0 Async

data

1

V.80 transparent synchronous mode

2

V.80 framed synchronous mode

Table 3-9. V.34 INFO bit report

Bits

Source bits

Definition

31-30

INFO0 bit 20; 0

20-29

INFOc bits 79-88

16-19

INFOc bits 26-29 or 35-38 or 44-
47 or 53-56- or 62-65 or 71-74

Pre-emphasis field, selected by the symbol rate
chosen

12-15

INFOa bits 26-29

10-11

MP bit 50; 0

0-9

INFOa bits 40-49