AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

102184B

Conexant

3-1

3

Data Command Set

3.1

Command Guidelines

The commands used to control and report modem operation in data modem mode are
defined in this section.

The Data Modem Mode commands and responses described in this section are applicable
when command +FCLASS=0. (See Section 3.2.1 for the definition of the FCLASS
command.)

The default values are typical of a fully configured modem supporting all data rates and
options. The actual default value is dependent upon installed modem firmware and
country specific parameters.

Commands are accepted by the modem once the previous command has been fully
executed, which is normally indicated by the return of an appropriate result code.
Execution of commands D and A, either as a result of a direct command or a re-execute
command, will be aborted if another character is entered before completion of the
handshake.

3.1.1

Escape Code Sequence

When the modem has established a connection and has entered on-line data mode, it is
possible to break into the data transmission in order to issue further commands to the
modem in an on-line command mode. This is achieved by the DTE sending to the modem
a sequence of three ASCII characters specified by register S2. The default character is '+'.
The maximum time allowed between receipt of the last character of the three escape
character sequence from the DTE and sending of the OK result code to the DTE is
controlled by the S12 register.

3.2

Data Commands

The modem will respond to the commands detailed below. Parameters applicable to each
command are listed with the command description. The defaults shown for each
configuration command are those used in the Conexant factory profile 0.