S36 - lapm failure control, S38 - delay before forced hang up – Comtrol AT Commands User Manual

Page 143

Advertising
background image

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

102184B

Conexant

3-117

S39 - Flow Control Bit Mapped Options Status

Default: 3 (00000011b)

Bits 0-2 Status of command options

0 =

No flow control

3 =

RTS/CTS (&K3) (Default.)

4 =

XON/XOFF (&K4)

5 =

Transparent XON (&K5)

6 =

Both methods (&K6)

Bits 3-7 Reserved

S40 - General Bit Mapped Options Status

S40 indicates the status of command options.

Default: 104 (68h) (01101000b)

Bits 0-1 MNP Extended Services (-Kn)

0 =

Disable extended services (-K0) (Default.)

1 =

Enable extended services (-K1)

2 =

Enable extended services (-K2)

Bit 2

Reserved

Bits 3-5 Break Handling (\Kn)

0 =

\K0

1 =

\K1

2 =

\K2

3 =

\K3

4 =

\K4

5 =

\K5 (Default.)

Bits 6-7 Reserved