+FRH - Receive Data with HDLC Framing

This command causes the modem to receive frames using HDLC protocol and the
modulation defined below. An ERROR response code results if this command is issued
while the modem is on-hook.

Syntax

+FRH=<mod>

Defined Values

<mod>

Decimal number corresponding to the selected modulation
mode and data rates shown in Table 4-2.

Reporting Current or Selected Values

Command: +FRH?

Response: +FRH:

<mod>

Example:

+FRH: 98

For V.17 9600 bps.

Reporting Supported Range of Parameter Values

Command: +FRH?

Response: +FRH?

Example:

+FRH: 98

For V.17 9600 bps.

Result Codes

CONNECT

Reported for either of two conditions:
1. When the selected carrier is detected with an HDLC flag.
2. If the DTE sends another +FTH=<MOD> command after

sending the result code indicating frame reception is
complete.

+FCERROR

Reported if a different carrier is detected and FAR=0.

NO CARRIER

Reported if loss of carrier is detected.

OK

Reported for either of two conditions:
1. If a frame was received correctly.
2. If the DTE sends any character other than XON or XOFF

while the modem is in the configured flow control.

ERROR

Reported if a frame was received in error.