Syntax, Defined values, Reporting current or selected value – Comtrol AT Commands User Manual

Page 82

Advertising
background image

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

Conexant

102184B

3-56

-TTE - Threshold Adjustments for Telephony Extension

This command allows the host to set/tune the telephone extension features for the modem
to determine Line In Use, Extension Pickup, Remote Hang-up, and Digital Line
Protection and Line Interruption Immunity conditions. An ATZ or AT&F will load
default values.

Syntax

-TTE=<Line In Use voltage drop threshold>, <Extension Pickup voltage drop
threshold>, <Remote Hang-up voltage drop threshold>, <Digital Line Protection
current threshold >, <Line Interruption Immunity >,<RESERVED>

Range: (0-9999)

1

, (0-9999)

1

, (0-9999)

1

, (0-9999), (0-255), (0-255)

Units: 1/10 volt (first three parameters), 1 mA (fourth parameter), 100 ms (fifth

parameter)

Defined Values

<Line In Use voltage drop threshold>

1

1000 = 10.00 V drop while modem is on-hook. (Default.)

<Extension Pickup voltage drop threshold>

1

150 = 1.50 V drop while modem is off-hook; this value must
be less than the Remote Hang-up voltage drop threshold.
(Default.)

<Remote Hang-up voltage drop threshold>

1, 2

500 = 5.00 V drop while modem is off-hook; this value must
be greater than the Extension Pickup voltage drop threshold.
(Default.)

<Digital Line Protection current threshold>

160 = 160 mA while modem is off-hook (Default.):

<Line Interruption Immunity>

0 = 200 ms (Default.)

1 = 200 ms

2 = 200 ms

n (where n > 2) = n*100 ms

<RESERVED>

056 (Default.)

Reporting Current or Selected Value

Command: AT-TTE?

Queries current setting

Notes:

1. Thresholds are difference thresholds. Example: The line would be considered “in

use” if the Tip & Ring voltage dropped by 10.00 V. Another Example: If the modem
is off-hook and the voltage drops by more than 2.50 V, then the modem would
consider the condition as an extension pickup.

2. The <Remote Hang-up voltage drop threshold> must always be less than the

<Extension Pickup voltage drop threshold). Otherwise, the extension pickup will not
function.