S-Parameter Definitions

S0 - Number of Rings to Auto-Answer

S0 sets the number of the rings required before the modem automatically answers a call.
Setting this parameter to zero disables auto-answer mode.

Range: 0-255

rings

Default: 0

S1 - Ring Counter

S1 is incremented each time the modem detects a ring signal on the telephone line. S1 is
cleared if no rings occur over an eight second interval.

Range: 0-255

rings

Default: 0

S2 - Escape Character

S2 holds the decimal value of the ASCII character used as the escape character. The
default value corresponds to an ASCII '+'. A value over 127 disables the escape process,
i.e., no escape character will be recognized.

Range: 0-255,

ASCII

decimal

Default: 43 (+)

S3 - Carriage Return Character

S3 sets the command line and result code terminator character. Pertains to asynchronous
operation only.

Range: 0-127,

ASCII

decimal

Default: 13 (Carriage Return)

S4 - Line Feed Character

S4 sets the character recognized as a line feed. Pertains to asynchronous operation only.
The Line Feed control character is output after the Carriage Return control character if
verbose result codes are used.

Range: 0-127,

ASCII

decimal

Default: 10 (Line Feed)