+IPR - Fixed DTE Rate

This numeric extended-format parameter specifies the data rate at which the modem will
accept commands during online operation. It may be used to select operation at rates at
which the modem is not capable of automatically detecting the data rate being used by
the DTE. Specifying a value of 0 disables the function and allows operation only at rates
automatically detectable by the modem. The specified rate takes effect following the
issuance of any result code(s) associated with the current command line.

The <rate> specified does not apply in OnLine Data State if Normal Mode (Direct Mode)
of operation is selected.

Syntax

+IPR=<rate>

Defined Values

<rate>

Specifies the DTE-modem interface operation rate in bits/s.
The available rates are: 0, 300, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200, or 230400

If unspecified or set to 0, automatic detection is selected and
the character format is also forced to autodetect, +ICF=0.

If the rate specified is not supported by the modem, an
ERROR result code will be returned

Reporting Current or Selected Values

Command: +IPR?

Response: +IPR:

<rate>

Example 1: +IPR: 0

For automatic rate detection.

Example 2: +IPR: 115200

For 115200 bps.

Reporting Supported Range of Parameter Values

Command: +IPR=?

Response: +IPR

(<rate>

range)

Example: +IPR:

(0,300,1200,2400,4800,9600,19200,38400,57600,115200,

230400)