Ste= - set telephony extension, Syntax, Defined values – Comtrol AT Commands User Manual

Page 76: Reporting current or selected values, Reporting supported range of parameter values, Result codes

Advertising
background image

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

Conexant

102184B

3-50

–STE= - Set Telephony Extension

The –STE command enables/disables Line In Use, Extension Pickup, and Remote
Hangup detection features.

Note: Additional hardware may be required to support these features.

Syntax

-STE=<value>

Defined Values

<value>

Decimal number corresponding to the selected bit-mapped
options. The bit fields are defined as follows:

Bit 0

Line In Use detection enable/disable.

Bit 1

Extension Pickup detection enable/disable.

Bit 2

Remote Hangup detection enable/disable.

<value>

(Dec.)

Remote
Hangup

Extension

Pickup

Line In Use

0 (default)

Disabled Disabled Disabled

1 Disabled

Disabled

Enabled

2

Disabled Enabled Disabled

3 Disabled

Enabled

Enabled

4 Enabled

Disabled

Disabled

5

Enabled Disabled Enabled

6 Enabled

Enabled

Disabled

7

Enabled Enabled Enabled

Reporting Current or Selected Values

Command: -STE?

Response: -STE: <value>

Example:

-STE: 4

Remote Hangup enabled, Extension
Pickup disabled, and Line In Use
disabled.

Reporting Supported Range of Parameter Values

Command: -STE=?

Show available options.

Response: -STE: 0-7

Result Codes

OK

<value> = 0-7

ERROR Otherwise.

Advertising