S91 - pstn transmit attenuation level, S92 - fax transmit attenuation level, S95 - extended result codes control – Comtrol AT Commands User Manual

Page 147

Advertising
background image

AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

102184B

Conexant

3-121

S210 – V.34 Symbol Rates

The bits in this parameter control V.34 symbols rates and enables/disables V.34
asymmetric rates. This parameter is used for diagnostic purpose only.

Default: 13 (0Dh) (00001101b)

Bits 0-2 Selects the range of allowed V.34 symbol rates.

2 1

0

Symbol Rates (baud)

0 0

0

= 2400 only

0 0

1

= 2400 only (no 2734)

0 1

0

= 2400, 2800

0 1

1

= 2400, 2800, 3000

1 0

0

= 2400, 2800, 3000, 3200

1 0

1

= 2400, 2800, 3000, 3200, 3429 (Default.)

Bit 3

Enable/disable V.34 asymmetric rates.

0 =

Disable asymmetric rates

1 =

Enable asymmetric rates (Default.)

Bits 4-7 Reserved.

Examples

S210=13 Enable asymmetric rates with all symbol rates available (Default.).

S210=5

Disable asymmetric rates with all symbol rates available.

S210=8

Enable asymmetric rates with only 2400 baud available.

S210=11 Enable asymmetric rates with 2400 to 3000 baud available.

Advertising