AT Commands for CX81801/CX06833/CX81300/CX06827 Modems Reference Manual

Conexant

102184B

3-10

&F - Restore Factory Configuration (Profile)

The modem loads the factory default configuration (profile). The factory defaults are
identified for each command and in the S-Parameter descriptions. A configuration
(profile) consists of a subset of S-Parameters.

Syntax

&F[<value>]

Defined Values

<value>

Decimal number corresponding to the selected configuration.

0

Restore factory configuration 0.

1

Restore factory configuration 1.

Result Codes

OK
ERROR

If the modem is connected.

&T - Local Analog Loopback Test

The modem will perform the local analog loopback test if &T1 is selected. The test can
be run only when in an asynchronous operation in non-error-correction mode (normal),
e.g., AT&Q6. To terminate the test in progress, the escape sequence must be entered first
(see Section 3.1.1).

Syntax

&T[<value>]

Defined Values

<value>

Decimal number corresponding to the selected option.

0

Terminates test in progress. Clears S16.

1

Initiates local analog loopback, V.54 Loop 3.
Sets S16 bit 0. If a connection exists when this
command is issued, the modem hangs up. The
CONNECT XXXX message is displayed upon
the start of the test.