Ele to camber – Futaba 8FGAS, 8FGHS 2.4GHz User Manual

Page 102

Advertising
background image

102

<Model Menu (Airplane/Glider Functions)>

● Select the function name

and return to the Model

menu by touching the

RTN button.

<SensorTouch™>

ELE to CAMBER

[Corresponding model type]: Airplane/glider, 2 ailerons or more

This function is used when you want to mix the

camber flaps with elevator operation. When used,

the flaps are lowered by up elevator, and lift is

increased.

● In-flight mixing can be turned ON/OFF by assigning

this to a switch. (Always ON at [--] setting)

● The mixing rate can be adjusted.

● The range that mixing does not work near the

neutral position of the elevator stick can be

adjusted. (Glider only)

Note: The elevator on the tailless wing will also

be effected when this mix is activated.

●Mixing rate adjustment

Move the cursor to the up or down mixing

rate item for each servo and touch the RTN

button to switch to the data input mode.

Adjust the rate independently by scrolling

the touch sensor.

Initial value: 0%
Adjustment range: -100~+100%

*When the RTN button is touched for one second, the rate is

reset to the initial value.)

Touch the RTN button to end the adjustment

and return to the cursor mode.

Setting method
●Activate the function

Move the cursor to the [ACT] item and touch

the RTN button to switch to the data input

mode. Select the ACT mode by scrolling the

touch sensor.

*The display blinks.

Touch the RTN button to activate the

function and return to the cursor mode. (ON

is displayed.)

When setting a switch, move the cursor to

the [SW] item and touch the RTN button to

call the selection screen. Select the switch

and set its ON direction. (Always ON at "--"

setting)

*For a description of the switch selection method, see the

description at the back of this manual.

●Range setting (Glider only)

Move the cursor to the [RANGE] item and

hold the elevator stick to the desired position

(upper or lower side) and then touch the RTN

button for one second to set the range.

*The mixing does not work near neutral of the elevator stick.

Initial value: 0%
Adjustment range: 0~100%

(Glider: Currently selected condition name)

● Select [ELE to CAMBER] at the Model

menu and access the setup screen

shown below by touching the RTN

button.

*The display screen is an example.

The actual screen depends on the

model type.

Scrolling

● Moving cursor

● Selecting mode

● Adjusting value

● To next page