Throttle limiter function – Futaba 8FGAS, 8FGHS 2.4GHz User Manual

Page 126

Advertising
background image

126

<Functions of Model Menu (Helicopter Functions)>

Throttle limiter function

Setting method

*Set at the 3rd page of the throttle curve screen.

•Activate the function.

1. Select ACT and touch the RTN button.
2. Switch the display to ACT by scrolling the

touch sensor.

*The display blinks.
INH: Inhibit
ACT: Activate
3. Enter the selection by touching the RTN

button.

•ON/OFF switch setting

1. Select SW and touch the RTN button.
2. The H/W SET screen is displayed. Select the

hardware and touch the RTN button.

•High side operating range setting

1. Select HIGH and touch the RTN button.
2. Adjust the high side operating range by

scrolling the touch sensor.

*A gauge is displayed at the left side of the graph.

3. Touch the RTN button to switch to the cursor

mode.

•Low side operating range setting

1. Select LOW and touch the RTN button.
2. Adjust the low side operating range by

scrolling the touch sensor.

*A gauge is displayed at the left side of the graph.

3. Touch the RTN button to switch to the cursor

mode.

This function limits the high range of the throttle

movement by any slider or trimmer.

*Control which adjusts the limit point during flight can be set.

•Limiter operating range adjustment control

setting

1. Select CTRL and touch the RTN button.
2. The H/W SET screen is displayed. Select the

hardware and touch the RTN button.

*The throttle limiter operating position is indicated by a

dotted line on the graph.

*When limiter operating range adjustment control is NULL,

the throttle limiter function is not performed.

•Changing the control center position

1. Select CENTER and touch the RTN button for

1 second. CENTER changes from INH to “rate

display”.

2. When the CENTER rate is changed, the

neutral position of the hardware set at CTRL

can be adjusted.

*When CENTER is INH, the neutral position becomes the

LOW intermediate value.

*When CENTER is changed from INH to “rate display”, the

CENTER rate is set to the LOW intermediate value.

*The CENTER rate can be set between HIGH and LOW.

[Throttle limiter setting]