Futaba 8FGAS, 8FGHS 2.4GHz User Manual

Page 83

Advertising
background image

83

<Model Menu (Common Functions)>

Dual rate setting procedure

1. Function selection
Move the cursor to the function selection

item and touch the RTN button to switch to

the data input mode.

Select the function you want to adjust by

scrolling the touch sensor.

Touch the RTN button to the cursor mode.
2. Switch selection
Move the cursor to the circuit # item and

access the switch setup screen by touching

the RTN button. Select the switch activation

method and the activation position (if

applicable).

*For a detailed description of the setting method, see [Switch

Setting Method] at the back of this manual.

3. Left/right (up/down) rate adjustment

*Perform the settings below after changing to the circuit # or

condition you want to adjust.

Move the cursor to the rate item you want to

adjust and touch the RTN button to switch to

the data input mode.

Adjust the rate by scrolling the touch sensor.
Initial value: 100%
Adjustment range: 0%~140%

*When the RTN button is touched for one second, the servo

operation position is reset to the initial value.)

Touch the RTN button to end the adjustment

and return to the cursor mode.

Repeat this procedure for additional rate

and other functions as desired.

4. Operation curve (EXP curve) adjustment

*Perform the settings below after changing to the circuit # or

condition you want to adjust.

Move the cursor to the EXP item you want to

adjust and touch the RTN button to switch to

the data input mode.

Adjust the rate by scrolling the touch sensor.
Initial value: 0%
Adjustment range: -100%~+100%

*When the RTN button is touched for one second, the servo

operation position is reset to the initial value.)

*Using the EXP curve is effective to smoothe or soften the

control inputs around center to avoid over-controlling the

model. This is often used for the ailerons, elevator and

rudder and may be used with the throttle in the case of an

airplane selection to smoothe the engine controls as well.

Touch the RTN button to end adjustment and

return to the cursor mode.

Repeat this procedure for all other rates and

functions as desired.

5. Neutral position adjustment

*Perform the settings below after changing to the circuit # or

condition you want to adjust.

Move the cursor to the [NT] item and touch

the RTN button to switch to the data input

mode.

Adjust the rate by scrolling the touch sensor.
Initial value: 0%
Adjustment range: -100%~+100%

*When the RTN button is touched for one second, the neutral

position is reset to the initial value.)

Touch the RTN button to the cursor mode.

Advertising