28

KFB/KFN-TM-BA_IA-e-1220

Press

and the current setting for the upper limit will be

displayed.

Press the navigation keys (See chap. 2.1.1) to enter the

upper limit, e.g. 1,100 kg; the currently enabled digit will be

flashing.

Confirm input by

.

Use

to select

Press

and the current setting for the acoustic signal will

be shown.

Select desired setting (no, ok, ng) by

.

Confirm input by

.

Press

repeatedly; weighing system is in tolerance

weighing mode. From here evaluation takes place whether

the goods to be weighed are within the two tolerance limits.

Weighing with tolerance range

Tare when using a weighing container

Put on goods to be weighed, tolerance control is started The signal lights

indicate whether the load is within the two set limits.

Load below specified

tolerance

Load within specified

tolerance

Load exceeds specified

tolerance

Red signal light

next to „-“ ON illuminated

Green signal light

next to „„ illuminated

Red signal light

next to „+“ ON illuminated

The tolerance control is not active when the weight is under 20d.

To delete limits, enter “00.000 kg“.