Certificate of EU type-approval no. DK 0199.202 rev.1

Issued by DELTA

Peripheral interface:

Set out in section 4

3.1.1

Connecting cable between the indicator and load cell / junction box for load cell(s)

3.1.1.1 4-wire system

Cable between indicator and load cell(s):

4 wires (no sense), shielded

Maximum length:

the certified length of the load cell cable, which

shall be connected directly to the indicator.

3.1.1.2 6-wire system

Only to be used for indicator model with a 7-terminal connector for load cell.

Cable between indicator and junction box:

6 wires, shielded

Maximum length:

227 m / mm²

3.2

Load receptors, load cells and load receptor supports

Removable platforms shall be equipped with level indicators.

3.2.1

General acceptance of modules

Any load cell(s) may be used for instruments under this certificate of type approval provided the fol-
lowing conditions are met:

1)

A test certificate (EN 45501) or OIML Certificate of Conformity (R60) respectively issued
for the load cell by a Notified Body responsible for type examination under the Directive
2009/23/EC.

2)

The certificate contains the load cell types and the necessary load cell data required for the
manufacturer’s declaration of compatibility of modules (WELMEC 2, Issue 5, 2009), and
any particular installation requirements). A load cell marked NH is allowed only if humidity
testing to EN 45501 has been conducted on this load cell.

3)

The compatibility of load cells and indicator is established by the manufacturer by means of
the compatibility of modules form, contained in the above WELMEC 2 document, or the
like, at the time of EC verification or declaration of EC conformity of type.

4)

The load transmission must conform to one of the examples shown in the WELMEC 2.4
Guide for load cells.

3.2.2

Platforms, weigh bridge platforms

Construction in brief

All-steel or steel-reinforced concrete construction, surface or pit
mounted

Reduction ratio

1

Junction box

Mounted in or on the platform

Load cells

Load cell according to section 3.2.1

Drawings

Various

3.2.3

Bin, tank, hopper and non-standard systems

Construction in brief

Load cell assemblies each consisting of a load cell stand assembly to
support one of the mounting feet bin, tank or hopper

Reduction ratio

1

Junction box

Mounted on dead structure

Load cell

Load cell according to section 3.2.1