8.2 Overview verified weighing systems

(contacts of circuit board [K1] short-circuited by means of jumper)

In verified weighing systems the access to „P2 mode and „P4 tAr“ is locked.

KERN KFB-TM:
To disable the access lock, destroy the seal and actuate the adjustment switch.

Position of the adjustment switch see chap. 6.11.
KERN KFN-TM

:

In order to unlock the access, the seal must be destroyed and both contacts of the

printed circuit board [K2] must be short-circuited by a jumper, see chap. 6.11.
Attention:

After destruction of the seal the weighing system must be re-verified by an

authorised agency and a new verification wire/seal mark fitted before it can be

reused for applications subject to verification.

Menu block
Main menu

Menu item
Submenu

Available settings / explanation

PO CHK

Weighing with

tolerance range,

see chap. 7.7

SET H

Upper limit value, input see chap. 7.7

SET LO

Lower limit value, input see chap. 7.7

PCS H

Not documented

PCS L

Not documented

BEEP

no

Acoustic signal for weighing with tolerance

range switched off

ok

Audio sound when load is within tolerance

limits

ng

Audio sound when load is beyond tolerance

limits