10 parts counting – KERN & SOHN FA 6T-3M User Manual

Page 32

Advertising
background image

32

KFB/KFN-TM-BA_IA-e-1220

7.10 Parts counting
Before the balance can count parts, it must know the average part weight (i.e.

reference). Proceed by putting on a certain number of the parts to be counted. The

balance determines the total weight and divides it by the number of parts, the so-

called reference quantity. Counting is then carried out on the basis of the calculated

average piece weight.

As a rule:

The higher the reference quantity the higher the counting exactness.

In weighing mode

, press and hold until the message „P

10“ appears that is used to set the reference quantity.

Use

to set the desired reference quantity (such as 100),

options include P 10, P 20, P 50, P100, P 200.

Place as many items to be counted (such as 100 items) as

demanded by the set reference quantity and confirm by

The weighing scales calculate the reference weight. The

current quantity (such as 100 items) will be displayed.

Remove reference weight. The balance is from now in parts

counting mode counting all units on the weighing plate.

Back to Weighing mode by

.

Advertising
This manual is related to the following products: