Connecting to bacnet interface module, Activate the battery, X-bac – LAARS M4-LHS - Installation Manual User Manual

Page 16: Alert, M4-lhs, M4ext, Extension, M4-lhs installation and operation manual, Battery, Bacnet interface module

Advertising
background image

HT# 059295-00

A

16

M4-LHS installation and Operation Manual

Connecting to BaCnet interface Module

• The M4-LHS can communicate to BACnet MSTP networks when used the X-BAC BACnet Interface Module (CA009100). The

module must be purchased separately.

• The BACnet Interface Module comes with an RJ45 cable.

• Both the M4-LHS and the BACnet Interface Module are equipped with a RJ45 socket (RS485) to connect to communicate to each

other.

• The Interface BACnet Module must be wired to the BACnet MSTP network using the RS485 terminals A, GND, and B.

• If both an extension panel and the BACnet Interface Module are to be used, connect the RJ11 socket on the BACnet Interface

Module to the extension.

Set the BACnet parameters. See "BACnet MSTP Communication Menu" on page 26.

BACnet Interface Module

MSTP

1

2

3

A GND B

PRODUCT

COMM

RS485

X-BAC

A
B
C
D

1 2

RUN

PROGRAM

DO NOT APPLY ANY VOLTAGE

TO INPUT TERMINALS

3 4 5 6 7 8 9 10 11 12

13

15

14

17

16

18

20

19

21

24

23

29

25

27

26

28

32

30 31

L N

-

+

+

T

T

O

O

RS-485

mA

GND

VLT

SYS

A

B

C

D

PWR

CUR / VLT

A

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

+

+

mA

22

-

GND

VLT

+

mA

TEMP

OUTDOOR

O

O

TEMP

SYSTEM

EXTENSION

MODULE

CUR / VLT

B

CUR / VLT

C

CUR / VLT

D

PROVE

/DHW

SHUTDOWN

/SETBACK

FOR ALL CIRCUITS

120VAC, 6A RESISTIVE

OUTPUT RATINGS:

1A PILOT DUTY, 15A TOTAL

115VAC 60Hz , 30VA MAX

INPUT RATINGS:

USE COPPER WIRE,

CLASS 1 WIRE ONLY.

CAUTION: RISK OF ELECTRIC SHOCK

More than one disconnect switch may be required

to de-energize the equipment before servicing.

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

99RA

/TSTAT

M4-LHS

HYBRID CONTROL

RJ45 Communication Cable

RJ45 Cable

Extension

RJ11 Extension Cable

RJ45

RJ11

RJ45

RJ11

F
H
J
Power

CAUTION:

Risk of Electric Shock.

More than one disconnect switch may be required

to de-energize the equipment before servicing.

PWR

L N
1 2

E

3 4

F

5 6

G

7 8

H

9 10

I

11 12

EXTENSION

MODULE

RS-485

Ext A

INPUT RATINGS:

115VAC 60Hz, 12VA MAX

Use Copper Conductors Only.

OUTPUT RATINGS:

120VAC, 6A RESISTIVE

1A PILOT DUTY, 15A TOTAL

FOR ALL CIRCUITS

E

G

I

Comm

Ext B

K
M
O

L
N
P

17

16

VLT

mA

CUR / VLT

20

19

16

VLT

mA

GND

CUR / VLT

23

22

19

VLT

mA

GND

CUR / VLT

26

25

22

VLT

mA

GND

CUR / VLT

J

13 14

K

M

O

L

N

P

E

F

G

H

K

M

L

N

15

GND

18

GND

21

GND

24

GND

29

28

VLT

mA

CUR / VLT

32

31

16

VLT

mA

GND

CUR / VLT

27

GND

30

GND

I

J

O

P

M4Ext

FULL MODULATION SEQUENCING EXTENSION

A (+)

Ground

B (-)

To BACnet

MSTP

aCTiVaTE THE BaTTErY

• The battery enables to control to maintain the clock time.

• Unscrew and remove the Enclosure Display Module to reveal the back of the control

CPU Board.

• Remove the plastic strap that covers the battery. The battery holder contacts should be

touching the battery. The control has a coin Lithium battery (CR2032) that is used to

maintain the control's time during power outages. This battery can maintain the clock for

up to a total of 100 days.

aLErT

Do not install the battery unless you plan to keep the control continuously powered. If the

control has no power, the battery will lose its charge in 100 days.

Battery