Day - night schedule, Set time, Maintenance – LAARS M4-LHS - Installation Manual User Manual

Page 36: System & outdoor sensor trim, M4-lhs, Alert, A b c d, 00 am, 35 pm, Hybrid control system & outdoor sensor trim

Advertising
background image

HT# 059295-00

A

36

M4-LHS installation and Operation Manual

DaY - NigHT SCHEDuLE

(Available when "Shutdown or Tstat" is selected from the Shutdown/Tstat/

Setback Startup menu option only)

Button: MENU/<System Settings>/<More Settings>/Day/Night Schedule

• The M4-LHS has two levels of heat. The Day (Normal) level is used when a building is

occupied and people are active.

• The Night (Setback) level is used when a building is not occupied, or when people are

sleeping. This setting reduces the calculated temperature by the Setback setting. See

"Setback" on page 31. If the Day calculated water temperature was 150˚F and the Setback

was 20˚F, the Night Schedule will run at (150˚F - 20˚F) = 130˚F.

• If the Boost feature is being used, it uses the Day Schedule as the Boost ending point. See

"Boost Mode" on page 25. That is, if the Day Schedule is set to start at 6:00AM, the Boost

will start 30 minutes prior to the Day setting at 5:30AM. The M4-LHS will then raise

the calculated water temperature by the Setback amount. Using the previous example,

at 5:30AM the M4-LHS will raise the calculated water to 170˚F = (150˚F + 20˚F) until

6:00AM.

DAY/NIGHT SCHEDULE

Set Time

**:**

Day Schedule 6:00a

Night Schedule

8:00p

BACK ▲ ▼ SAVE

-- DAY SCHEDULE --

6:00 Am

BACK ▲ ▼ SAVE

Set Time

Button: MENU/<System Settings>/<More Settings>/Set Time

• Adjust the time by selecting Set Time from the menu and then scrolling through the hours

then select Save. If the hours are to be set to PM, scroll through the AM hours to reach the

PM hours. Then, scroll through the minutes then select Save.

----- SET TIME -----

7:35 Pm

BACK ▲ ▼ SAVE

aLErT

Remember that the battery is the backup for the Time. If no power is supplied to the M4-LHS and

there was no battery or the battery had no power, time values will be lost and will need to be reset.

MaiNTENaNCE

Button: MENU/<Maintenance>

The Maintenance menu gives access to sensor and modulating output trimming. In addition,

you'll have access to view the Startup configuration settings.

aLErT

To be able to change the M4-LHS settings the Program/Run Switch must be

set to Program. The switch is located under the Enclosure Wiring Cover for

security. The Enclosure Wiring Cover can be secured using a lock.

----- MAINTENANCE ----

System Trim

+0

o

F

Outdoor Trim

0

o

F

<Output Trim>

<Configuration>

BACK ▲ ▼ SAVE

SYSTEM

A
B
C
D

1 2

RUN

PROGRAM

DO NOT APPLY ANY VOLTAGE

TO INPUT TERMINALS

3 4 5 6 7 8 9 10 11 12

13

15

14

17

16

18

20

19

21

24

23

29

25

27

26

28

32

30 31

L N

-

+

+

T

T

O

O

RS-485

mA

GND

VLT

SYS

A

B

C

D

PWR

CUR / VLT

A

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

+

+

mA

22

-

GND

VLT

+

mA

TEMP

OUTDOOR

O

O

TEMP

SYSTEM

EXTENSION

MODULE

CUR / VLT

B

CUR / VLT

C

CUR / VLT

D

PROVE

/DHW

SHUTDOWN

/SETBACK

FOR ALL CIRCUITS

120VAC, 6A RESISTIVE

OUTPUT RATINGS:

1A PILOT DUTY, 15A TOTAL

115VAC 60Hz , 30VA MAX

INPUT RATINGS:

USE COPPER WIRE,

CLASS 1 WIRE ONLY.

CAUTION: RISK OF ELECTRIC SHOCK

More than one disconnect switch may be required

to de-energize the equipment before servicing.

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

99RA

/TSTAT

M4-LHS

HYBRID CONTROL

System & Outdoor Sensor Trim

Adjustable from -5F°/-3C° to +5F°/+3C°

Default: 0°F

Button: MENU/<Maintenance>/System Trim

Button: MENU/<Maintenance>/Outdoor Trim

• The Laars thermistor type sensors are very accurate, and normally require no calibration.

Sometimes it may be desirable to make small adjustments to the displayed value for either

the Outdoor Temperature (OD) or the System Temperature (SYS). The Trim setting is used

to adjust the displayed value.

• Do not use the Trim setting to make the Outdoor Temperature sensor match that reported

on the radio or TV. Outdoor Temperature can vary widely over a broadcast range. Only

trim the outdoor sensor based on an accurate thermometer reading taken where the sensor is

located.

SYSTEM SENSOR TRIM

+0

o

F

[

]

BACK ▲ ▼ SAVE

OUTDOOR SENSOR TRIM

+0

o

F

[

]

BACK ▲ ▼ SAVE

Advertising