Basic troubleshooting – PRG Bad Boy Field Service Manual User Manual

Page 27

Advertising
background image

BAD BOY

®

SPOT LUMINAIRE FIELD SERVICE MANUAL

19

Basic Troubleshooting

The following table provides a list of common start-up problems and possible solutions. Refer to the Bad Boy Spot
Luminaire User Manual for more information about installation and operation.

Symptom

Solution(s)

No power to luminaire.

Ensure power cable is properly connected to Neutrik input connector.

Ensure power is switched on at source (mains, disconnect box, etc.)

No console control.

Ensure DMX512 or Ethernet data cable is properly connected.

Ensure DMX512 address setting is correct.

DMX512 control not working correctly
throughout daisy-chain.

Ensure data cables are correctly configured.

Ensure termination connector is installed at last luminaire in data link.

Lamp does not strike at power-up.

Configure lamp to start at power-up.

Comm LED is red indicating that no valid
DMX or Ethernet signal is detected.

Ensure DMX512 or Ethernet data cable is properly connected.
Check console.

No Ethernet control.

Ensure that luminaire is not also receiving a DMX signal. If both valid DMX and
Ethernet control are being received, DMX control will take precedence.

Beam obstructed by gobo in open position.

Set new gobo zero position.

Luminaire won’t take software update.

Remove active control (DMX512 or Art-Net).