Cleaning the Enclosure Intake Filters

The intake filters should be cleaned or replaced when they are dirty. The frequency will depend on how often and in
what conditions the luminaire is used.

Parts:

40-9812-0834

2 EA

AIR INTAKE FILTER

Tools:

#2 Phillips screwdriver
Compressed air

and/or

water

To clean enclosure intake filters:

WARNING:

Remove power from luminaire before performing any maintenance procedures.

Step

1. Remove power from luminaire.

Step

2. Remove Intake Cover by first loosening two captive screws, then pulling away from Upper Enclosure as

shown in Figure 3-6.

Figure 3-6: Removing Enclosure Intake Filters

Step

3. At retainer, remove four 6-32 x 1/2" PPZ screws.

Step

4. Remove intake filter.

Step

5. Clean filter with compressed air and/or by washing with water.

Step

6. Re-install components.

Step

7. Repeat for second intake filter.

Intake Cover

Captive Screws

Upper Enclosure

Mesh Cover

Intake Filter

Retainer

6-32 x 1/2"

Intake Filter

PPZ Screw (4)

NOTE:

If the filters do not get clean after multiple
attempts, they should be replaced.