Adjusting the lamp – PRG Bad Boy Field Service Manual User Manual

Page 52

Advertising
background image

44

BAD BOY

®

SPOT LUMINAIRE FIELD SERVICE MANUAL

Adjusting the Lamp

After a new lamp is installed, it will be necessary to align the lamp in order to center and flatten the hot spot. Knobs
located at the luminaire’s backcap allow for adjustment.

Tools:

none

WARNING:

Backcap may be HOT during lamp operation.

To adjust lamp:

Step

1. Power up luminaire and allow to warm up for at least ten minutes.

Step

2. Set intensity to 100%.

Step

3. Position beam on a white wall at a distance of 10' to 20'.

Step

4. Using control console, open beam size iris, set zoom for mid-range, and adjust for hard edge.

Step

5. At backcap, using horizontal (X) and vertical (Y) knobs, adjust hot spot to center of beam (Figure 3-12.)

Step

6. Using focus (Z) knob, adjust beam to flatten hot spot.

Figure 3-12: Adjusting the Lamp

Note: Be sure to reset Lamp Hours when installing a new lamp.

X

Y

Z

Advertising