B.1 Initializing Bus

IFC:

Initializes functions of all the devices connected to the GPIB bus line, when the GPIB option is

mounted.

Initialization of the interface function refers to an action of canceling the status of the interface function

of the device set by the controller and returning it to the initial status. Each function marked with a

check mark (vi) in the table is initialized. The function marked with a delta (A) means that the function

will be partially initialized. This command has no effects on the operation status of the device.

Table B-1 Changes in Status of Interface Functions by IFC Message

Appendix B Details of Initialization Command Functions

No.

Function

Cord

Initialization by IFC

I

Source handshake

SH

V

2

Acceptor handshake

AH

V

3

Talker or extension talker

T orTE

4

Listener or extension listener

L or LT

V

5

Service request

SR

A

6

Remote local

RL

7

Parallel port

PP

8

Device clear

DC

9

Device trigger

DT

10

Controlle

C

V

The following table shows changes in status of the device by the IFC message.

Table B-2 Changes in Status of Device by IFC Message

IFC Message

Changes in Status of Device

Talker/Listener

All the talkers and listeners switch into the idle state (TIDS and LIDS) within 100 ps.

Controller

Unless the controller is active (SACS: System control ACtive State), the controller switches

into the idle state (CIDS: Control IDle State) within 100 ps.

Device of service request

Although the state where the device is sending an SRQ message to the controller (state

where the SRQ line is set by the device to the LOW level) is not canceled, the message

cancels the state where the controller have all the devices under the system bus in the serial

pole mode.

Device in remote mode

Devices currently in the remote mode will not be released from the remote mode by the IFC

message.