Section 8 Device Message Details

: SENSe : TELecom : RANGe <range>

Command type

Parameter

Function

Example of use

Sequential command

<range> = <CHARACTER PROGRAM DATA>

UI4 ...............

4 UI

pp

UIl ................ 1 UI

pp

Sets the measurement range of receiving jitter.

Sets the measurement range of receiving jitter at 1

UI

pp

.

> : SENSe : TELecom : RANGe UIl

: SENSe : TELecom : RANGe?

Command type

Response

Function

Example of use

Sequential command

<range> = <CHARACTER RESPONSE DATA>

Makes a query of receiving jitter measurement.

> : SENSe : TELecom : RANGe?

< UIl

: SENSe : TELecom : FILTer <filter>

Command type

Sequential command

Parameter

<filter> = <CHARACTER PROGRAM DATA>

LP.................. LP

(80 M)

HPILP............HPl+LP

(10 K to 80 M)

HPISLP......... HPl’+LP

(20 K to SOM)

HP2LP...........HP2+LP (4 M to 80 M)

HP3LP...........HP3+LP (6 M to 80 M)

HPLP.............HP+LP

(12 K to SOM)

HPSLP...........HP'+LP

(50 K to 80 M)

Function

Performs filter setting.

Restriction

HP’+LP, HPl'+LP setting

is disabled

when the Bit Rate is set at 2.5 G or 5 G.

HP3+LP can be set only for Option 07.

Example of use

Sets the filter at HP'+LP, HPl’+LP.

> ; SENSe : TELecom : FILTer HPSLP