Motion Control Theory

e Set up protection mechanism:

Set up a protection mechanism to power off the motor
automatically when the error position is exceeding this

deviation limit. Set the limit to zero to close this

mechanism. In addition, the motor automatically turns off
when a warning or emergency signal is encountered.

f

Start calculation and display outcome:
You can initiate the process once all the settings are
made. The frequency response outcome displays in the
MCP2 Bode plot page as shown in figure below, where
the motor has null load and resolution at 10000
pulse/rev, the sine wave amplitude is set at 300 pulse
with 100 data points, each point's update cycle is 0.1 sec
and frequency range is 10Hz~100Hz.

Table of the Bode plot's parameters

Name

Unit

Range

Description

Start Frequency

Hz

>0

Frequency of sine wave

End Frequency

Hz

>0

Frequency of sine wave

Sine amplitude

Pulse

>0

Amplitude of sine wave

Data Length

Value

>1

Total data length of Bode plot

Update

Second

>0

Update time of each Bode plot
data

Deviation limit

Pulse

>=0; This function will be
ignored if it is set to 0.

If error position exceeds
deviation limit, the servo will be
disable immediately.