Motion Control Theory

4.10.5 Simultaneous Move

4.10.5.1

Simultaneous Start

Synchronized (Simultaneous) start: This movement can set to be
enabled by trigger. When proper command is received, the axis
enters a waiting-for-trigger-signal status and starts moving after
the trigger is received. When multiple axes are in waiting-for-
trigger-signal status you may send trigger signal at the same time
for synchronized enabling. Please note that movement of each
axis is independent from each other and so the end time varies
with offset amount and acceleration profile.

Please enables simultaneous start by steps below:

a Set axis movement to triggered startup and check the

axis status for waiting for trigger

b Send the trigger to run synchronized start

a Set axis movement to triggered startup and check the

axis status for waiting for trigger

You may set up the startup-by-trigger mode by the Option
parameter of the controller's function. The axis enters
trigger waiting status once the command is received.

Take APS_ptp, the function prototype may look like

I32 APS_ptp( I32 Axis_ID, I32 Option, … );

See table below for definitions of Option. Please note that
given axis is set to startup-by-trigger mode when Bit 8 is
given value 1.

7

6

5

4

3

2

1

Bit : 0

Absolute(0) /

Relative(1)

15

14

13

12

11

10

9

8

Buffer mode

Wait trigger