Figure 4-6, Table 4-3, Pci-8254/8 auto-tuning setup – ADLINK PCI-8258 User Manual

Page 97

Advertising
background image

Motion Control Theory

83

PCI-8254 / PCI-8258

Figure 4-6: The auto fine tuning setup page in MCP2

Table 4-3: PCI-8254/8 Auto-Tuning setup

Setup

Descriptions

Setup range

Default

Offset limit
Deviation Limit

The maximum difference
between position command
and feedback. The program
stops when this value is
exceeded and ignored it if it is
set to zero.
(UOM: pulse)

>=0

2000

Amplitude

Set up vibration amplitude of
output signal
(UOM: Volt)

0~10

1

Axis

Designate axis for running
auto fine tuning procedure

0~7

0

Data length
Data Length

Calculate required hysteresis
range

>0

200

Hysteresis

Hysteresis range
(UOM: pulse)

>0

50

Sampling time
(Cycle Time)

Encoder sampling time
(UOM: micro-second)

100~1000

500

Advertising