130
Motion Control Theory
NOTE
NOTE
1. Motion control input signal EMG, ALM, PEL,
and MEL may lead to movement termination.
Please refer to safety protection related
sections.
2. In continuous mode the target position may be
updated from time to time (so does the
command position).
3. When control axis is in jog movement, other
movement commands is disabled to prevent
malfunctions.
4. When the control axis is running other
movements (e.g. home movement) the jog
command will be ignored.