130

Motion Control Theory

NOTE

NOTE

1. Motion control input signal EMG, ALM, PEL,

and MEL may lead to movement termination.
Please refer to safety protection related
sections.

2. In continuous mode the target position may be

updated from time to time (so does the
command position).

3. When control axis is in jog movement, other

movement commands is disabled to prevent
malfunctions.

4. When the control axis is running other

movements (e.g. home movement) the jog
command will be ignored.