5 pel/mel input, Pel/mel input, 50 signal connection – ADLINK PCI-8258 User Manual

Page 64

Advertising
background image

50

Signal Connection

3.5 PEL/MEL Input

PCI-8254/PCI-8258 provides 4/8 End-limited switch input
channels. The Plus Limited Switch (PEL) is used as the
mechanical protection switch for movement in the positive
direction. When this switch is triggered, the PCI-8254/PCI-8258
stops its positive direction movement immediately. The Minus
Limited Switch (MEL) is used as the mechanical protection switch
for movement in the negative direction. When this switch is
triggered, the PCI-8254/PCI-8258 stops its negative direction
movement immediately. See below for corresponding pins of
mechanical limit switch signal input on DIN-825-GP4:

J1/J2 Pin No

Signal Name

Description

Axis #

3

PEL(3) / PEL(1)

Plus limit switch input (3) / (1)

3 / 1

7

PEL(4) / PEL(2)

Plus limit switch input (4) / (2)

4 / 2

5

MEL(3) / MEL(1)

Minus limit switch input (3) / (1)

3 / 1

9

MEL(4) / MEL(2)

Minus limit switch input (4) / (2)

4 / 2

NOTE

NOTE

PCI-8258 need two DIN-825-GP4 for eight axes motion control
functions
# 1 controls axes 1 ~ 4 and #2 controls axes 5 ~ 8

Advertising
This manual is related to the following products: