11 compare & trigger output, Figure 3-12 – ADLINK PCI-8258 User Manual

Page 71

Advertising
background image

Signal Connection

57

PCI-8254 / PCI-8258

3.11 Compare & Trigger Output

PCI-8254/PCI-8258 provides 2/4 comparing trigger pulse output
channels. Each comparing trigger channel can output pulse
commands up to 1 MHZ. See Section 4.9.2 for its detail and how
to use it. See below for corresponding pins of pulse command
output against differential pulse signals to DIN-825-GP4:

• Signal connection diagram:

1. Line Driver interface:

Figure 3-12: Line Driver type compare trigger signal connection example

J3 Pin No

Signal Name

Description

2

TRG2-/TRG4-

Trigger output (-), (2)/(4)

3

TRG2+ / TGR4+

Trigger output (+), (2)/(4)

4

TRG1-/TRG3-

Trigger output (-), (1)/(3)

5

TRG1+/TRG3+

Trigger output (+), (1)/(3)

NOTE

NOTE

The compare trigger pulse output channel of
PCI-8254/PCI-8258 employs line driver output interface for
better noise signal resistance and wiring length where trigger
output (3) & (4) require #2 DIN-825-GP4 for wiring.