174

Motion Control Theory

Table below suggests power range and resolution that can be set
up by different control modes' VAO tables.

4.10.3.4

Output Settings

The VAO module now supports 4 PWM output channels for users'
selection. You may set multiple channels to output the same
control signals at the same time. Individual VAO modules are now
opened with specific APS_start_vao() functions.

Mode

Power output range

Resolution

1. PWM mode

Duty cycle: 0~2000

(0.05%~100%)

0.05%

2. PWM frequency mode with
fixed width

Frequency: 3Hz ~ 50MHz

1 Hz

3. PWM frequency mode with
fixed duty cycle

Frequency: 3Hz ~ 50MHz

1 Hz