3 • OMR

3-8

SV61656 Rev. A

OMR Mark Grouping

Each OMR code begins with two fixed marks at the end nearest to

the sensor (benchmark and safety mark). These are followed by one,

two, or three groups of marks where each group comprises three

data marks followed by a fixed mark. Each data mark is present or

absent as required to reflect the function desired. Each code must

end with a retiming mark.
Basic OMR mode uses only Group 1.
Enhanced OMR mode uses Group 1 plus Group 2 and/or Group 3,

as needed for a particular job.

C-Fold and Double Fold Jobs

Place marks in the upper left corner of the sheet. Print marks in top-

to-bottom order:

Benchmark (fixed)

Safety (fixed)

Not EOC

Not BOC

Parity

Retiming (fixed)

Select Feed 1

Select Feed 2

Auto Batch

Retiming (fixed if this group is in use)

Wrap Around Sequence 3 (WAS3)

Wrap Around Sequence 2 (WAS2)

Wrap Around Sequence 1 (WAS1)

Retiming (fixed if this group is in use)

Print sheets in reverse collation order. In this way, the last sheet

processed in each set is the address sheet and the first sheet pro-

cessed is the last of each set.

Group 1

(Mandatory)

Group 2

Group 3

Feed Direction