Problem

Remedy

Page

DOUBLE DETECT

Machine Stops for Doubles that Aren’t There or Feeds Doubles

without Stopping
Double detect is

not turned ON.

Check double detect status. Double

detect icon will appear alongside

all items for which double detect is

ON.
Correct loading or job setup as nec-

essary.

Chapter

2

Double detect is

not correctly cali-

brated.

Run a trial piece whenever you load

a new batch of material to recali-

brate double detect. The new batch

might have sheets that vary slightly

in thickness from the old batch.

2-3