Factory & User Configurations

Configuration & Reset Buttons

The Nios development board uses dedicated switches SW8, SW9 and
SW10 for the following fixed functions:

SW8 – CPU Reset

When SW8 is pressed, a logic-0 is driven onto the Stratix II I/O pin AA15
(DEV_CLRn). The result of pressing SW8 depends on how the Stratix II
device is currently configured.

The factory-programmed Nios II reference design treats SW8 as a CPU-
reset pin (see

Figure 2–16

). The Nios II reference design will reset and

start executing code from its reset address when SW8 is pressed.

Figure 2–16. CPU Reset Button

SW9 – Factory Config

Pressing Factory Config (SW9) commands the configuration controller to
re-configure the Stratix II device with the factory configuration.

SW10 – Reset, Config

Reset, Config (SW10) is the power-on reset button (see

Figure 2–17

).

When SW10 is pressed, a logic 0 is driven to the power-on reset controller
(U18). See

“Power-Supply Circuitry” on page 2–35

for more details. After

SW10 is pressed, the configuration controller will load the Stratix II
device from flash memory.