C o mmo n E r ro r s

Errors 001 to 405 and 429 to 435 are data errors. This type of error
indicates that incorrect data was sent to the printer, and the printer is
ignoring it. Your System Administrator should correct the packet and send it
back to the printer.

Error

Description/Action

002

Name must be 1 to 8 characters (excluding non-printable control
characters) inside quotes.

005

Supply width is invalid.

018

Code page selection defined in the field must be 0 (Internal), 1
(ANSI), 100 (Macintosh), 101 (W ingdings), 102 (UNICODE), 103
(BIG5 for UNICODE), 104 (GB2312 for UNICODE), 105 (SJIS for
UNICODE), 106 (GB2312), 107 (BIG5), 437 (DOS Page 437),
850 (DOS Page 850), 852 (Latin 2), 855 (Russian), 857
(Turkish), 860 (Portuguese), 1250 (Latin 2), 1251 (Cyrillic), 1252
(Latin 1), 1253 (Greek), 1254 (Turkish), 1255 (Hebrew), 1256
(Arabic), 1257 (Baltic), or 1258 (Vietnamese).

025

Data length is too long.

101

Format referenced by batch not in memory.

400

Invalid character following {.

403

Field separator was not found.

409

Printer memory is full. Delete unnecessary formats or graphics
from memory.

410

Parity mismatch.

411

Framing error (baud rate mismatch).

412

Flow control mismatch.

413

Online receive buffer is full. Check for a flow control problem.

Advertising