Pacific Research Solutions RI-200 User Manual

Page 39

Advertising
background image

Pacific Research Solutions

RI-200 User Manual

Page 38

4.5.40

DELAY TIMER MACRO TRIGGER

You can delay a macro to execute at some time in the future. Once this S-Command is setup and the timer expires, the macro
pointed to by the “Start Line” field will execute. Note: This function will generate an “OK” function complete without a user
command being sent. For example, this function can be used to turn on the CTCSS repeater tone panel after a preset time has
expired.

SYNTAX:

40 [Start Line] [Time]

MINIMUM:

Start Line 000 (disable function), Time 0 (reset timer)

MAXIMUM:

Start Line 999 (macro start line), Time 7200 (seconds, 2 hours)

UNITS:

Start Line 000 = Disable this function, Start line 001 – 999 Macro data start line
Time 0 = Reset timer, 1 – 7200 seconds (2 hours maximum)

DEFAULT:

Start Line = 000, Time = 0

EXAMPLE:

40 000 0

Clears the timer, no macro will execute.

40 060 120

Execute macro at start line 60 in 2 minutes.

4.5.41

RECEIVER INACTIVITY TIMER MACRO TRIGGER

The receiver inactivity timer can be used to reset the system when the repeater receiver becomes inactive for the preset time.
Once the S-Command is setup, the timer is restarted each time the receiver activity goes away. When a time out occurs the
macro pointed to by the “Start Line” field will execute. Note: This function will generate an “OK” function complete without
a user command being sent. For an example, this function can be used to turn on the CTCSS tone decode after there has been
no activity on the repeater for the set time.

SYNTAX:

41 [Start Line] [Time]

MINIMUM:

Start Line 000 (disable function), Time 0 (reset timer).

MAXIMUM:

Start Line 999 (macro start line), Time 2400 (in 6 second increments).

UNITS:

Start Line 000 = Disable this function, Start line 001 – 999 Macro data start line.
Time 0 = Reset timer, 1 – 2400 in 6 second increments (1 to 240.0 minutes).

DEFAULT:

Start Line = 000, Time = 0.

EXAMPLE:

41 000 0

Clears the timer, no macro will execute.

EXAMPLE:

41 022 55

Execute macro at start line 22 in 5.5 minutes.

4.5.42

REGULAR INTERVAL MACRO TRIGGER

This command is used to trigger a macro start line at a regular timed interval. If you want to have a beacon ID every hour,
you can use this command to trigger a macro line that starts the ID.

SYNTAX:

42 [Start Line] [Time]

MINIMUM:

Start Line 000 (disable function), Time 0 (reset timer).

MAXIMUM:

Start Line 999 (macro start line), Time 240 (minutes).

UNITS:

Start Line 000 = Disable this function, Start line 001 – 999 Macro data start line.
Time 0 = Reset timer, 1 – 240 in minutes.

DEFAULT:

Start Line = 000, Time = 0.

EXAMPLE:

42 123 10

Trigger macro starting at line number 123 every 10 minutes.

42 000 0

Disable this feature.