System

Command

System Command Description

and Data Format

Command

Syntax

Factory

Setting

Pwr on

Recover

50

Squelch adjust
Adj = 0 to 63 or * up one count, # down one count

50 [Adj]

31

Yes

51

Set squelch mode
Mode 0 = Normal, Mode 1 = SmartSquelch

51 [Mode]

1

Yes

52

Setup squelch
Item 1 = Upper threshold, Value = 75 to 200
Item 2 = Lower threshold, Value = 50 to 150
Item 3 = Acquisition time, Value = 0 to 50 in 10 ms increments
Item 4 = Delay factor, Value 0 to 255
Item 5 = Average factor, Value 0 to 50
Item 6 = Weak signal threshold, Value 3 to 50 in 10 ms inc.

52 [Item] [Value]

Item

1 = 160
2 = 130

3 = 8

4 = 125

5 = 25

6 = 5

Yes

53

Reserved

53 [ ]

N/A

N/A

54

Set Key code (prefix) for macros
Key = 0 to 4 digits (C and D are NOT VALID)

54 [Key]

0

Digits

Yes

55

Set Password for S-Cmd access
PW = 1 to 6 digits

55 [PW]

123456

Yes

56

Set Password for telephone incoming ring access
PW = 1 to 6 digits

56 [PW]

343

Yes

57

Set Password for telephone incoming control access
PW = 1 to 6 digits

57 [PW]

654381

Yes

58

Remote software reset
Controller Serial Number (SN) is 8 digits

58 [SN]

Serial

Number

N/A

59

Remote EEPROM initialize
Controller Serial Number (SN) is 8 digits

59 [SN]

Serial

Number

N/A

60

User telephone commands
Cmd # = 01 – 08, Group = 1 – 8
Line = 000 to 999, Name = 1 - 4 digits

60 [Cmd #]

[Group] [Line]

[Name]

See sec.

4.5 60

Yes

61

User S-Commands commands, call S-Command
Cmd # = 01 – 21, Group = 1 – 8
S-Cmd = 00 to 99, Name = 1 - 4 digits

61 [Cmd #]

[Group] [S-Cmd]

[Name]

See sec.

4.5.61

Yes

62

User commands
Cmd # = 01 – 08, Group = 1 – 8
Line = 000 to 999, Name = 1 to 4 digits

62 [Cmd #]

[Group] [Line]

[Name]

See sec.

4.5.62

Yes

63

Macro and message editor, set starting line number pointer
Line = 1 to 999

63 [Line]

N/A

N/A

64

Macro editor, insert an S-Command
S-Cmd/Data = 00 to 99 and its data as req. for the S-Cmd
No S-Cmd/Data for end of macro marker

64 [S-Cmd/Data]

See

Section

4.5.64

Yes

65

Reserved

N/A

N/A

66

Reserved

N/A

N/A

67

Reserved

N/A

N/A

68

Jump to macro line
Line = 1 – 999

68 [Line]

N/A

N/A

69

Exit system command mode

69

N/A

N/A