Ri-200 repeater controller system command list – Pacific Research Solutions RI-200 User Manual
Page 78
Pacific Research Solutions
RI-200 User Manual
Page 77
RI-200 REPEATER CONTROLLER SYSTEM COMMAND LIST
System
Command
System Command Description
and Data Format
Command
Syntax
Factory
Setting
Pwr on
Recover
34
Auxiliary output mode
Mode 0 = Off, 1 = COS, 2 = AUX CTCSS/DCS,
3 = COS and AUX CTCSS/DCS, 4= Open squelch
34 [Mode]
0
Off
Yes
35
Auxiliary input mode
Input = 0 – 8, 0 = All inputs
State 1 = Enable (on), 0 = Disable (off)
Mode 1 = Mix audio, 0 = Mute audio
Source = 0 – 8, Aux CTCSS/DCS source for encode,
0 = Disable
35 [Input] [State]
[Mode] <Source>
0
All off
Yes
36
AUX input, repeater carrier delay time
Time = 0 to 255 in 1/10 second increments
36 [Time]
10
1.0 Sec
Yes
37
Regenerate DTMF from AUX input
1 = Enable (on), 0 = Disable (off)
37 [Mode]
0
Off
Yes
38
Multiple controller data link protocol mode
Mode 0 = digital data, 1 = serial data, 2 = Clone controller
38 [Mode]
1
serial data
Yes
39
Controller Unit Address, serial communication
Address = 1 through 9
39 [Address]
1
Yes
40
Delay timer macro trigger
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 – 7200 Seconds, 0 = Reset timer
40 [Line] [Time]
0
disable
No
41
Receiver inactivity timer
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 to 240.0 Minutes in 6 seconds increments
41 [Line] [Time]
0
disable
No
42
Schedule to trigger a macro at a regular interval
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 to 240 Minutes
42 [Line] [Time]
0
disable
Yes
43
Set time clock
Time = HHMM in 24 hour mode
43 [Time]
Not
Set
No
44
Schedule to trigger a macro
Sch = Scheduler 1 to 8
Time = HHMM in 24 hr mode
Line = Macro starting line number 0 to 999, 0 = Disable
44 [Sch] [Time]
[Line]
0
disable
Yes
45
Bit input, trigger a macro on state change
Bit = 1-3 (Input number), 4 = COS, 5 = CTCSS/DCS,
6 = PTT, 7 = Aux in COS, 8 = Aux in CTCSS or DCS,
9 = Aux in active
State 0 = Inactive or falling edge (Hi to Lo)
State 1 = Active of rising edge (Lo to Hi)
Line = Macro starting line number 0 to 999, 0 = Disable
45 [Bit] [State]
[Line]
0
Disable
Yes
46
Bit output on/off
Bit = 1-3 (Bit number)
Mode 1 = On, 0 = Off
46 [Bit] [Mode]
0
off
No
47
Bit output pulse on for time
Bit = 1-3 (Bit number)
Time = 0 to 255 in 1/10 second increments
47 [Bit] [Time]
0
No
48
Reserved
48 [ ]
N/A
N/A
49
Dial Click Control Trigger
Click = 1-9, Line = Macro starting line 0 to 254, 255 = disable
39 [Click] [Line]
0
Disabled
Yes