Ri-200 repeater controller system command list – Pacific Research Solutions RI-200 User Manual

Page 78

Advertising
background image

Pacific Research Solutions

RI-200 User Manual

Page 77

RI-200 REPEATER CONTROLLER SYSTEM COMMAND LIST

System

Command

System Command Description

and Data Format

Command

Syntax

Factory

Setting

Pwr on

Recover

34

Auxiliary output mode
Mode 0 = Off, 1 = COS, 2 = AUX CTCSS/DCS,
3 = COS and AUX CTCSS/DCS, 4= Open squelch

34 [Mode]

0

Off

Yes

35

Auxiliary input mode
Input = 0 – 8, 0 = All inputs
State 1 = Enable (on), 0 = Disable (off)
Mode 1 = Mix audio, 0 = Mute audio
Source = 0 – 8, Aux CTCSS/DCS source for encode,
0 = Disable

35 [Input] [State]

[Mode] <Source>

0

All off

Yes

36

AUX input, repeater carrier delay time
Time = 0 to 255 in 1/10 second increments

36 [Time]

10

1.0 Sec

Yes

37

Regenerate DTMF from AUX input
1 = Enable (on), 0 = Disable (off)

37 [Mode]

0

Off

Yes

38

Multiple controller data link protocol mode
Mode 0 = digital data, 1 = serial data, 2 = Clone controller

38 [Mode]

1

serial data

Yes

39

Controller Unit Address, serial communication
Address = 1 through 9

39 [Address]

1

Yes

40

Delay timer macro trigger
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 – 7200 Seconds, 0 = Reset timer

40 [Line] [Time]

0

disable

No

41

Receiver inactivity timer
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 to 240.0 Minutes in 6 seconds increments

41 [Line] [Time]

0

disable

No

42

Schedule to trigger a macro at a regular interval
Line = Macro starting line number 0 to 999, 0 = Disable
Time = 0 to 240 Minutes

42 [Line] [Time]

0

disable

Yes

43

Set time clock
Time = HHMM in 24 hour mode

43 [Time]

Not

Set

No

44

Schedule to trigger a macro
Sch = Scheduler 1 to 8
Time = HHMM in 24 hr mode
Line = Macro starting line number 0 to 999, 0 = Disable

44 [Sch] [Time]

[Line]

0

disable

Yes

45

Bit input, trigger a macro on state change
Bit = 1-3 (Input number), 4 = COS, 5 = CTCSS/DCS,
6 = PTT, 7 = Aux in COS, 8 = Aux in CTCSS or DCS,
9 = Aux in active
State 0 = Inactive or falling edge (Hi to Lo)
State 1 = Active of rising edge (Lo to Hi)
Line = Macro starting line number 0 to 999, 0 = Disable

45 [Bit] [State]

[Line]

0

Disable

Yes

46

Bit output on/off
Bit = 1-3 (Bit number)
Mode 1 = On, 0 = Off

46 [Bit] [Mode]

0

off

No

47

Bit output pulse on for time
Bit = 1-3 (Bit number)
Time = 0 to 255 in 1/10 second increments

47 [Bit] [Time]

0

No

48

Reserved

48 [ ]

N/A

N/A

49

Dial Click Control Trigger
Click = 1-9, Line = Macro starting line 0 to 254, 255 = disable

39 [Click] [Line]

0

Disabled

Yes