4.5.84

TELEPHONE NUMBER AUTO-DIALER

The RI-200 supports 99 auto dial numbers and a last number re-dial. Use this command to store each of the auto dial
numbers. Any number stored here will not be checked by the accept and reject tables when used. To access a stored auto dial
number when sending the telephone user off-hook command, include * and the auto dial storage number 01 through 99. *00
is reserved to recall last number re-dial. When using auto dial numbers, the auto dial number is not stored into the last
number re-dial buffer. Valid digits are 0 through 9, *, # and A for a 2 second pause.

SYNTAX:

84 [Store position] [Telephone number]

MINIMUM:

Store position 01, Telephone number 0 digits (clears auto dial number)

MAXIMUM:

Store position 99, Telephone number 16 digits

UNITS:

See above

DEFAULT:

Nothing stored.

EXAMPLE:

84 01 15306729053

Store Pacific Research Solutions number in auto dial position 01

84 00

Clear last number re-dial buffer

4.5.85

SET AN AUTO-DIAL NUMBER FOR USE

This S-Command is used to set an Auto-Dial number in a macro for use in dialing a telephone number within a macro. This
S-Command must be placed before the off-hook S-Command 82 in the macro. If this S-Command is used in a normal
telephone dialing macro, this command will delete any number or auto dial code that was included in the users dialing
process. This command is best used if you are building a macro that has a normal user command and will dial a
preprogrammed number for the user.

SYNTAX:

85 [Auto dial position]

MINIMUM:

00 (Last number redial)

MAXIMUM:

99 (End of the Auto Dial table)

UNITS:

Auto dial store positions

DEFAULT:

N/A

EXAMPLE:

85 14

Dial number stored in auto dial position 14 when off-hook occurs in the macro.

4.5.86

TELEPHONE NUMBER ACCEPT TABLE ENABLE

This command will turn on/off the accept number table. If the accept table is off and the reject table is on, only numbers that
do not match the reject table will be available for dialing. See section 6, telephone interconnect, of additional information on
use of the accept and reject tables.

SYNTAX:

86 [on/off]

MINIMUM:

0

MAXIMUM:

1

UNITS:

0 = Off and 1 = On

DEFAULT:

0

EXAMPLE:

86 1

Turn on the accept table.