PrimeTest 350 Operating

Instructions

- 84 -

The test will run until the countdown timer in the
Duration field has reached zero.

Note: During the test, the mains cord should be
flexed at the points of entry into the equipment and
the mains plug. Changes in the reading may
indicate damage to the protective earth conductor
or a poor connection.

At the end of the test duration, the PrimeTest 350 will
compare the last reading with the Limit to determine
the outcome of the test. If the last reading is lower than
the Limit, a Pass result is recorded. This is indicated on
the display by a large tick mark next to the
measurement field, as shown below.

Similarly, if the last reading is greater than the Limit, a
Fail result is recorded. This is indicated by a large
cross next to the measurement field as shown below.