96

An NEPS3500-A AC power frame can function properly only after you install one or two

NEPS1800-A AC power modules to it.

Table 38 Electrical parameters of power system

Model Description

Rated input

voltage range

Max input

voltage range

Max input

current

Max output power

NEPS3500-
A

3500 W AC
power frame

100 VAC to 240
VAC @ 50 Hz or
60 Hz

90 VAC to 264
VAC @ 50 Hz
or 60 Hz

16 × 2 A

3500 W (when
installed with two
AC power modules)

NEPS1800-
A

1800 W AC
power
module

100 VAC to 240
VAC @ 50 Hz or
60 Hz

90 VAC to 264
VAC @ 50 Hz
or 60 Hz

16 A @ 110

V

12 A @ 220

V

1200 W @ 100

VAC to 120 VAC

1800 W @ 200

VAC to 240 VAC

NEPS2000-
A

2000 W AC
power

module

100 VAC to 240
VAC @ 50 Hz or

60 Hz

90 VAC to 264
VAC @ 50 Hz

or 60 Hz

16 A

2000 W

NEPS800-A

800 W AC
power

module

100 VAC to 240
VAC @ 50 Hz or

60 Hz

90 VAC to 264
VAC @ 50 Hz

or 60 Hz

12 A @ 100 V 800 W

NEPS1300-
D

1300 W DC
power
module

–36 VDC to –72
VDC

–72 VDC to
–38.4 VDC

46 A @ –48 V 1300 W

NEPS2000-
D

2000 W DC
power

module

–36 VDC to –75
VDC

–72 VDC to
–40 VDC

45 A @ –48 V 2000 W

NEPS3500-
D

3500 W DC
power

module

–36 VDC to –75
VDC

–72 VDC to
–40 VDC

80 A @ –48 V 3500 W

Table 39 16 A AC power cords used in different countries or regions

1

Connector
type

Code (Length)

Countries or regions
where the type of

power cords conforms
to local safety

regulations and can be

used legally

Other countries or
regions using this type of

power cords

Countries or
regions seldom
using this type of

power cords

I type

04043396 (3
m/9.8 ft)

Mainland China

Connector outline

Power cable outline

Connector outline

Advertising