Item LSUM1AC2500 specifications

LSUM1DC2400 specifications

Temperature
requirements

Operating temperature: –10°C to
+50°C (14°F to 122°F)

Operating temperature: –10°C to
+50°C (14°F to 122°F)

Storage temperature: –40°C to +85°C
(–40°F to +185°F)

Storage temperature: –40°C to +85°C
(–40°F to +185°F)

You can select a certain number of power modules according to the actual power consumption
requirements. Make sure that the total maximum output power of the ordered power modules is greater

than the system power consumption. H3C recommends that you reserve 20% of the maximum output

power.

NOTE:

Power modules of different models cannot be installed on the same gateway.

When the temperature of a power module exceeds the normal operating temperature, the power
module is automatically powered off. When the temperature recovers to the normal temperature, the

power module is automatically powered on.

Fan trays

Table 21

shows the fan trays that each M9000 gateway supports. Every M9000 gateway comes with

fan trays installed.

Table 21 Fan tray specifications

Fan tray

Number of fans Fan diameter

Maximum

rotating speed

Maximum air

flow rate

M9006 fan tray

8

92 mm (3.62 in)

6000 RPM

960 CFM

M9010 fan tray

12

120 mm (4.72 in)

5200 RPM

1152 CFM

M9014 upper fan tray 8

120 mm (4.72 in)

5200 RPM

1040 CFM

M9014 lower fan tray 4

120 mm (4.72 in)

5200 RPM

720 CFM

NOTE:

When the fan tray is damaged and needs to be replaced, select a new fan tray compatible with your
gateway.

Air filters

CAUTION:

Clean air filters periodically (at least once every three months) to guarantee adequate ventilation and
avoid over-temperature.

To prevent dusts from entering the chassis, you can configure air filters for the gateway as needed and

install the air filters at the air inlet vents.