K2 Storage Area Network Installation and Service Manual

26 October 2009

Chapter 9 Operating the K2 SAN

Powering on Level 10, 20, 30, and Nearline 10 RAID storage
devices

Use the following procedure to power on and verify proper operation of RAID storage
devices.

Powering on the HP ProCurve switch

Use the following procedure to power on and verify proper operation of the HP
ProCurve switch.

1. Power up the switch.

2. Watch LEDs to verify proper operation. The diagnostic self test LED Behavior is

as follows:

• Initially, all the status, LED Mode and port LEDs are on for most of the duration

of the test.

• Most of the LEDs go off and then may come on again during phases of the self

test. For the duration of the self test, the Test LED stays on.

If the ports are connected to active network devices, the LEDs behave according to
the LED Mode selected. In the default view mode (Link), the LEDs should be on.

• If the ports are connected to active network devices, the LEDs behave according

to the LED Mode selected. In the default view mode (Link), the LEDs should be
on.

• If the ports are not connected to active network devices, the LEDs will stay off.

Powering on the control point PC

Use the following procedure to power on K2 SAN’s control point PC and verify
proper operation during power up of the system.

1. Power up and log on to the PC using standard Windows procedures.

2. Start and log on to NetCentral.

3. NetCentral reports devices as offline. As each device of the K2 SAN is powered

on, check NetCentral to verify the device’s status

FTP on K2 SANs

Refer to the K2 System Guide for FTP information.