CMD12 (3Ch) — Mute Selected Outputs

The Host tells the Matrix to mute specific planes within selected outputs.

Format: CMD12, Mute1, Mute2, ... Mute

n, Cks1, Cks2, EOT

Where: MuteX specifies planes to be muted for the output corresponding to the

mute byte number. This uses the same format as PlnMap shown below.

PlnMap0 to access the RGBS Switcher (planes 1, 2, 3 & 4)

Plane #

n/a

7

6

5

4

3

2

1

Plane Use

n/a

n/u

Audio

Sync/

Sync/

Blue

Green

Red

Stereo Video

Video HRAM HRAM HRAM

PlnMap Bit #

7

6

5

4

3

2

1

0

MuteX

1

0

x

x

x

x

x

x

Example: Assume an 8 x 8 switcher, with RGBS, Composite video and Audio.

3Ch, 87h, A0h, 90h, 97h, 80h, 80h, 80h, 80h, Cks1, Cks2, 04h

The following outputs are muted:
87h

Output 1:

R, G, B (leave sync on)

A0h

Output 2:

Audio Stereo (Left + Right)

90h

Output 3:

Composite video

97h

Output 4:

R, G, B and Composite video

80h

Outputs 5 - 8:

Outputs not muted

Response: CMD12, Erc, Cks1, Cks2, EOT

CMD13 (3Dh) — Request Mute Map

The Host asks the Matrix to send which outputs are muted. The response sends
back the same data in the same format as CMD12.

Format: CMD13, Cks1, Cks2, EOT

Example: 3Dh, 80h, BDh, 04h

Response: CMD13, Erc, Mute1, Mute2, ... Mute

n, Cks1, Cks2, EOT

Where: MuteX specifies planes to be muted for the output corresponding to the

mute byte number. This uses the same format as PlnMap shown above.

CMD14 (3Eh) — Set Sequence

The Host tells the Matrix 200 to create a Sequence of presets and store it under
a specified Sequence number. The command also specifies how long each
preset will run (be active).

Format: CMD14, Seq#, {(PSet#, Hr, Min, Sec, CR), ..} Cks1, Cks2, EOT

Where: SEQ# Sequence number (1 to 31).

(PSET#, Hr, Min, Sec, CR) repeat this string for each Preset that will be
part of the Sequence. Each Preset string will become a sequence “step”.

PSet# Preset number (1 to 20)
Hr

Number of hours to run (0 to 17)

Min

Number of minutes to run (0 to 59)

Sec

Number of seconds to run (0 to 59)

Notes: 1. Maximum number of sequences is 31.