Function Menu (7)

This menu provides access to different operational functions of the Matrix 200. It
has three submenus:

LED/LCD Contrast Submenu.
Tie Level Access Submenu.
Vertical Interval Switching Submenu.

To select this menu, press Menu, followed by “7”.

Selecting Function Submenus

With the Function Menu displayed, use the cursor keys to position the cursor at
position 0,0. Use the Up/Down cursor keys to sequence through the three
submenus (LCD/LED CTL, VERT INT, TIE LEVEL) until the desired submenu is
displayed.

Tie Level Access Submenu (menu 7)

This submenu determines the state transitions in the Tie Menu.
There are three choices:

• The “ALL” level affects connections at all switching levels (planes).
• The “RGB, AUD, VID” level affects connections only for the predefined
“gangs” of switching levels (planes). These gangs are related to the three
keys on the Front Panel.
• The “INDIVIDUAL” level permits independent changes to each level (plane).

1. With the Tie Level Submenu displayed, and the cursor at position 1,4, use the

Up/Down cursor keys to sequence between the three tie levels (ALL, RGB,
AUD, VID or INDIVIDUAL) until the desired tie level is displayed.

2. Press the Enter key to save tie level to SmartControl memory.

3. Press the Escape key to return to the default menu.

Vertical Interval Switching Submenu (menu 7)

This menu allows the Vertical Interval switching to be enabled or disabled. When
Enabled, Matrix switching is done using only the vertical sync of the input signal
of the Video Genlock connector at the rear of the Matrix 200. (See picture below,
right.) When Disabled, switching takes place immediately, independent of the
Video Genlock signal. If Enabled, and there is no Genlock input, switching will
take place after a slight delay.

1. With the Vertical Interval Submenu displayed and the cursor at position 1,8,

use the Up/Down cursor keys to toggle between Enable
and Disable, and display the desired mode.

2. Press the Enter key to save the mode to SmartControl

memory.

3. Press the Escape key to return to default menu.