Chapter 4 • using the front panel controller – Extron Electronics Matrix 200 User Manual

Page 55

Advertising
background image

Extron • Matrix 200 • User’s Manual

Chapter 4 • Using the Front Panel Controller

Copying a Sequence (menu 5)

When creating a new sequence, it may be easier to make a copy of an existing
sequence and then edit the copy. The new, edited copy will be assigned a new
sequence number. To make a copy of an existing sequence, do the following:

1. With the cursor at the upper left corner of the LCD display (position 0,0), use

the Up/Down keys to select the Copy Submenu. Observe that sequence “01”
is displayed in the top row, and a “To” sequence number is in the lower right.

_______ This example copies Seq 01 to Seq 02.

2. To change either of these sequence numbers, use the Left/Right keys to step

to the location of the number(s) to be changed.

3. At the top-right, enter the number (01-32) of the sequence to copy using the

keys of the numeric keypad.

4. Move the cursor to the bottom row of the LCD display (positions 1,13-14) and

enter the sequence number (1-32) assigned to the new copy.

5. Press Enter to make the copy.

_______ The two sequences (01 & 02) are now identical. Use the Sequence Edit menu to

make changes to the new sequence.

Start a Sequence (menu 5)

1. To start a sequence, place the cursor at the upper left corner of the LCD
display (position 0,0). Use the Up/Down keys to select the Operation
Submenu. (See picture.)

2. With the cursor at the 1,9 position, use the Up/Down cursor keys to scroll

through the menu choices until “START” appears in the LCD display.

3. Use the Left/Right keys to step the cursor to the SEQ position and enter the

number of the sequence to be started.

4. Press Enter to start the sequence.

_______ The sequence will continue running in a loop (repeat) until it is stopped.

The Start Menu is replaced by a Stop Menu. Only one sequence can run at a
time.

Stop the Sequence (menu 5)

When a sequence is running, the “Enter To Stop” menu (left) appears in place
of the Operation Menu. Press Enter to stop the sequence that is running. The
Stop Menu is now replaced by the Operation Start menu.