Appendix B • Programming Guide

Command List (Host-to-Matrix)

Command

Hex

Page

Description

CMD0

30

B-8

request status (requires SCMD)

CMD1

31

B-9

request System ID information (requires SCMD)

CMD2

32

B-9

turn power ON

CMD3

33

B-10

turn power OFF

CMD4

34

B-10

request software version

CMD5

35

B-12

set (tie) single connection

CMD7

37

B-12

set (tie) all connections

CMD8

38

B-13

request status and presets

CMD9

39

B-13

mute all planes

CMD10

3A

B-13

save current as preset #

CMD11

3B

B-13

load preset #

CMD12

3C

B-14

mute selected outputs

CMD13

2

3D

B-14

request Mute map

CMD14

2

3E

B-14

create a sequence of presets and save it

CMD15

2

3F

B-15

request stored sequence (saved presets)

CMD16

2

40

B-15

operate sequence (start/stop/resume/delete/
copy)

CMD17

2

41

B-15

request a list of all saved presets

CMD18

2

42

B-16

set program to start on time & date

CMD19

2

43

B-16

request program that has been setup

CMD20

2

44

B-16

operate program (delete)

CMD22

46

B-16

set the clock

CMD23

47

B-17

request the clock information

CMD24

48

B-17

set Executive mode

CMD25

49

B-17

set RGB delay (after sync, for clean switching)

CMD26

4A

B-17

request RGB delay setting

CMD27

4B

B-18

set baud rate for host controller

CMD28

4C

B-18

request the baud rate for a port

CMD29

4D

B-18

set operating mode (vertical switching, slave,

etc.)

CMD31

2

4F

B-19

set slave mode with specified coordinates

CMD32

2

50

B-19

request slave coordinates

CMD33

51

B-19

identify port

CMD34

52

B-19

set security password

CMD35

53

B-20

security operations (requires SCMD)

CMD36

54

B-20

set audio parameters (requires SCMD)

CMD37

55

B-22

request audio parameters (requires SCMD)

Reports (Matrix-to-Host)

RPRT0

70

B-23

report status to host

RPRT1

71

B-23

report controlling port

Communication Control

CR

0D

carriage return

EOT

04

end of transmission

X-On

11

resume transmission

X-Off

13

interrupt transmission

B-7

2

Not supported by

Matrix 200, version 1.0
software.

SCMD = Subcommand, a