Appendix b • programming guide, B-17 – Extron Electronics Matrix 200 User Manual

Page 105

Advertising
background image

Extron • Matrix 200 • User’s Manual

Appendix B • Programming Guide

CMD23 (47h) — Request the Clock Information

The Host asks the Matrix for its clock settings.

Format: CMD23, Cks1, Cks2, EOT

Example: 47h, 80h, C7h, 04h

Response: CMD23, Erc, Yr, Mo, Day, Hr, Min, Sec, Cks1, Cks2, EOT

Possible Ercs: C4 = Clock not set

CMD24 (48h) — Turn Executive Mode On/Off

The Host requests the Matrix to turn Executive Mode on/off.

Format: CMD24, Mode, Cks1, Cks2, EOT

Where: Mode = 80h turn Executive mode On
81h turn Executive mode Off

Example 1: 48h, 80h, 81h, C8h, 04h

Response: CMD24, Erc, Cks1, Cks2, EOT

Example 2: 48h, 81h, 81h, C9h, 04h

Response: CMD24, Erc, Cks1, Cks2, EOT

CMD25 (49h) — Set RGB Delay

The Matrix is instructed to set values for RGB delay. When switching occurs, the
R, G and B switching will take place after the specified time delay. The sync
switching takes place immediately, but the RGB outputs are muted during this
delay period. This allows the projector to get in sync before the picture arrives,
providing seamless switching.

Format: CMD25, Dly1, Dly2, .... Dly

n, Cks1, Cks2, EOT

Where: Bits 0-6 of DlyX represent the RGB-to-sync delay for output X
(expressed in increments of 0.1 sec). The “

n” represents the number of outputs

as determined by command CMD1. (Dly1 = output #1; Dly2 = output #2,
etc.)

Delays must be specified for each output. For zero time delay, DLY =
80h. The time delay depends on the requirements of the output device
(projector, etc.).

Example: 49h, 84h, 90h, etc. says the RGB for output #1 will be delayed by 0.4

seconds, and output #2 will be delayed by 1.6 seconds, etc.

Response: CMD25, Erc, Cks1, Cks2, EOT

CMD26 (4Ah) — Request RGB Delay Information

The Host asks the Matrix to send delay switching information for the RGB
planes.

Format: CMD26, Cks1, Cks2, EOT

Example: 4Ah, 80h, CAh, 04h

Response: CMD26, Erc, Dly1, Dly2, .... Dly

n, Cks1, Cks2, EOT

Where: DlyX characters have the same significance as in previous command.

See decimal/binary/hex
conversion table on page B-2.

B-17

Advertising
This manual is related to the following products: