background image

CAUTION!

Exceeding 30 VDC can damage the transmitter. Terminal current must be less than 500 mA.

Recommended pull-up resistor versus supply voltage

Figure 9-7:

3600

3200

2800

2400

2000

1600

1200

800

0

5

10

15

20

25

30

Supply voltage (Volts)

External pull-up resistor range (Ohms)

4000

4400

9.3.3

Internally powered frequency output wiring on Channel

C

I/O wiring for Model 2700 transmitters with configurable input/outputs