Externally powered discrete input wiring, 2 externally powered discrete input wiring – Emerson MICRO MOTION 1700 User Manual

Page 112

Advertising
background image

Internally powered discrete input wiring

Figure 9-20:

A

A.

Switch

9.5.2

Externally powered discrete input wiring

Externally powered discrete input wiring

Figure 9-21:

A

B

C

A.

PLC or other device

B.

VDC

C.

Direct DC input

Power is supplied by either a PLC/other device or by direct DC input.

Input voltage ranges for external power

Table 9-2:

VDC

Range

3–30

High level

0–0.8

Low level

0.8–3

Undefined

I/O wiring for Model 2700 transmitters with configurable input/outputs

108

Micro Motion

®

Model 1700 and 2700

Advertising